FLAGSHIP PRODUCT · 220kV / 440kV

MoniTachThe Tachyons Yard Intelligence

Autonomous 11kV–440kV Switchyard & Control Panel Intelligence.

Real-time condition monitoring, predictive fault diagnostics and remote actuation for EHV yards and substation control panels — eliminating manual hazardous inspections near live high-voltage terminals.

Proprietary system engineered by Tachyons Energy. Supervises and reports alongside your protection scheme; remote actuation is permission-controlled, interlocked and logged.

Bay supervision

SIMULATED
  • CBBay breaker positionCLOSED
  • SF6Compensated gas densityNORMAL
  • TCSTrip circuit supervisionHEALTHY
  • THMBusbar joint R-phaseWATCH
  • FOFibre link · yard PLCUP
Continuous supervision
24×7
Galvanic isolation
Optical fibre
Substation & field protocols
IEC 61850 · Modbus
Alarm escalation
SMS / voice

LIVE DEMO

Experience the MoniTach operator console

A simulated 220kV / 440kV operator console running in your browser — the views your control-room team would work from.

SIMULATED DATA · for demonstration

MoniTach

Switchyard & control panel remote monitoring

0
Simulated data · Demonstration consoleFIBRE LINK · OKPLC · ONLINEModbus TCP · 1 s pollIEC 61850 · MMS / GOOSEFEED · STANDBY· --:--:--

Bay 204 · 220kV Feeder-1

LINE ENERGISED
BUS-A220kV MAIN BUS220.1 kV89ACLOSEDCB 52CLOSEDCT1200/1A420 ACVT220.1 kVLINEENERGISED154.5 MW
Bus kV
220.1 kV
Line I
420 A
Line
220.1 kV
Power
154.5 MW

Simulate a condition

Applies to Bay 204 · 220kV Feeder-1 · watch the cards and the event log

Circuit breaker 52

NORMAL
CB stateCLOSEDLine energised

Last operation

—

by Remote operator

Operations

1284

Contact life

87.4%

Closing springCHARGED

Motor current · peak 11.4 A · 6.0 s run

Trip-circuit supervision
TC11.82 mAHEALTHY
TC21.79 mAHEALTHY

Healthy ≥ 1.2 mA · continuous

Close interlocks

  • SF6 density above lockout: satisfied
  • Lockout relay 86 reset: satisfied
  • Isolator 89A closed: satisfied
  • Closing spring charged: satisfied

Two-step select → execute · selection disarms after 5 s · every command is logged

SF6 gas density

NORMAL
RATED6.0ALARM5.2LOCKOUT5.0

Density @20°C

6.00bar

Measured

6.35bar

Gas temp

37.2°C

Temp-compensated · rated 6.0 bar

Trend · 60 s

Busbar & feeder

ON LOAD

Busbar kV · 3-phase

V R-Y

220.4

V Y-B

219.8

V B-R

220.2

Line I

420A

Active

154.5MW

Reactive

42.0MVAr

PF

0.965

Freq

50.00Hz

Apparent

160.1MVA

I · 3φ SCOPERYB

Line current · 60 s

Thermal monitoring

NORMAL
  • CB contact · R-phase46.2°CNORMAL
  • CB contact · Y-phase45.1°CNORMAL
  • CB contact · B-phase46.8°CNORMAL
  • Cable termination43.4°CNORMAL
  • Busbar joint40.6°CNORMAL
  • Termination · 60 s

Scale 20–110 °C│ Warning ≥ 75 °C│ Hotspot ≥ 90 °CAmbient 31 °C

Interconnecting transformer

NORMAL

OTI · oil

58.4°C

WTI · winding

66.9°C

OLTC tap · AVR auto

09 / 17

Buchholz · NORMALPRV · NORMALCooling · ONAF

Alarm & event log0 unack

  1. Connecting to edge gateway…

In production, unacknowledged alarms escalate automatically by SMS and voice call to the on-call engineer.

No one entered the yard to read these values.

Simulated data · values and scenarios are illustrative, not from a live substation

INTERACTIVE ARCHITECTURE

What the System Monitors

Select any monitored component to trace its signal from the field sensor, through the yard PLC and optical fibre, to the control-room gateway, dashboard and alerting — and to see exactly what is measured.

System architecture · yard → fibre → control room

Monitoring architecture: EHV yard sensors to yard PLC, optical fibre to the control room edge gateway, SCADA dashboard and alerting. Selected: SF6 Gas Density & Pressure.EHV YARD220kV / 440kV switchyardOPTICAL FIBREnon-conductive linkCONTROL ROOMpanels · gateway · dashboardCONTROL & DISTRIBUTION PANELSGALVANIC ISOLATIONno copper path yard ↔ control roomIEC 61850 · Modbus over fibreYARD PLCdata concentratorEDGE GATEWAYprotocol + historianSCADA / WEBoperator dashboardALERTINGSMS · voice · escalationCBCircuit BreakerSF6SF6 CompartmentPTPower TransformerISOIsolator / ESTCSTrip CircuitTHMThermal / BusbarMFMFeeder Telemetry

Tap a component in the diagram, or use the list below (arrow keys move between items).

Monitored components

220kV / 440kV Yard Components

Control & Distribution Panel Components

220kV / 440kV Yard Components

SF6 Gas Density & Pressure

Supervised 24×7

Parameters monitored

  • Continuous real-time SF6 gas pressure
  • Temperature-compensated density
  • Early micro-leakage alarms
  • Density trend against lockout and alarm stages

Sensing method · typical

Density transmitter with integral temperature compensation, mounted on the compartment alongside (not replacing) the existing density monitor contacts; 4–20 mA or Modbus output to the yard PLC.

Early warning looks like

A slow, steady decline in compensated density over days or weeks while still above the alarm stage — the signature of a micro-leak at a flange, seal or valve.

Action it enables

Plan leak detection and gas top-up before the density reaches the breaker’s own low-density alarm or operation-block stage.

Signal path

  1. Density transmitter
  2. Yard PLC / data concentrator
  3. Optical fibre
  4. Edge gateway
  5. SCADA / web dashboard
  6. SMS / voice escalation

A supervision and reporting layer: protection relays and their trip schemes remain fully in charge of clearing faults. Sensor types, sampling intervals and alarm set-points shown here are typical and are configured per site with the O&M team.

COMMUNICATION & INTEGRATION

Speaks IEC 61850 for modern substations, and Modbus for everything else

MoniTach connects to a substation the way that substation is built: over the IEC 61850 station bus where IEDs are networked, over Modbus for meters and PLCs, and by hardwired signals for legacy equipment.

  • MODERN SUBSTATIONS

    IEC 61850

    For digital and newly built substations, MoniTach joins the station bus as an IEC 61850 client and reads the IEDs directly, without duplicating sensors that the protection and control system already has.

  • METERS · PLCs · SENSORS

    Modbus TCP / RTU

    Multifunction meters, yard PLCs, gas-density transmitters and thermal sensors are polled over Modbus, on Ethernet or RS-485, and carried to the control room on optical fibre.

  • LEGACY EQUIPMENT

    Hardwired I/O

    Older electromechanical gear is covered with potential-free contacts and 4–20 mA signals wired to the yard data concentrator, so a mixed-age yard appears on one dashboard.

IEC 61850 services used

Station bus · fibre Ethernet

MMS
Client connection to protection relays, bay control units and other IEDs: status, measurements, reports and logs read from their data models.
GOOSE
Subscription to fast status and event messages on the station bus, so breaker and interlock changes reach the dashboard as they happen.
Reports & datasets
Buffered and unbuffered reports, so events raised while a link is down are not lost.
SCL files
Engineering from the substation configuration (ICD / CID / SCD) files, so signal names match the scheme drawings.

How it sits on the network

  • Reads, does not protect. MoniTach subscribes to and reports on IED data. Protection tripping and interlocking stay with the protection and control scheme.
  • Redundant paths. Designed to work on redundant station-bus networks (PRP / HSR) where the substation uses them.
  • Common time base. Events are time-stamped against the station clock (SNTP or PTP), so sequences line up with relay records.
  • One dashboard. IEC 61850, Modbus and hardwired signals are normalised at the edge gateway and shown together.

Protocol scope, IED list and northbound interfaces are fixed per project from the signal list.

OPERATIONAL & SAFETY CASE

Key Operational & Safety Advantages for the Power Sector

What changes for the people who run the yard: fewer exposures near live equipment, cleaner data paths, and maintenance that is planned rather than forced.

01 · SAFETY

Eliminate Direct Human Contact with HV Terminals

Operators no longer need to enter energized 220kV/440kV switchyards or open live control panels to read gauges, check SF6 pressure, or verify breaker states — drastically reducing arc-flash and electrocution risks.

  • Routine readings move to the control room
  • Yard entry reserved for planned, permitted work
02 · ISOLATION

Optical Fiber Galvanic Isolation

Complete electrical isolation between the high-voltage switchyard field sensors/PLCs and the central control room dashboard, preventing ground potential rise (GPR) and EMI/RFI surges from travelling into control-room equipment.

  • Non-conductive link between earth systems
  • Immune to induced switching transients on the route
03 · PREDICTIVE

Predictive Maintenance over Reactive Outages

Catch degrading trip coils, rising terminal temperatures, or slow SF6 leaks weeks before a catastrophic grid trip occurs — and plan the fix into a scheduled outage instead of an emergency one.

  • Trends against commissioning baselines
  • Set-points tuned with your O&M team
04 · COMMAND

Centralized Multi-Substation Command

Unify legacy and modern substation gear into a single, intuitive web/SCADA dashboard with instant SMS, voice and escalation alerts to the engineers on call.

  • Legacy contacts and modern IEDs side by side
  • Alarm acknowledgement and escalation trail

BEFORE / AFTER

From yard rounds to continuous supervision

The same O&M duties, carried out without putting people next to live terminals to collect the data.

Gauge reading
Manual: Technician walks the yard on a schedule and notes OTI / WTI and other dial values by hand.
Remote: Values streamed continuously and trended; readings available at any hour from the control room.
SF6 check
Manual: Density gauges read near energised breakers during rounds; a slow leak shows only between visits.
Remote: Temperature-compensated density tracked live, with micro-leak trend alarms ahead of the breaker’s own alarm stage.
Breaker state verification
Manual: Position confirmed visually at the bay or by phone between yard and control room.
Remote: Auxiliary-contact status, spring charge and trip-circuit health shown per bay on the dashboard.
Thermal inspection
Manual: Periodic handheld IR surveys, often with panel doors opened on live equipment.
Remote: Fixed sensors at terminations, joints and contacts; hotspot rise flagged as it develops.
Fault investigation
Manual: Reconstructed from relay flags, logbooks and recollection after the event.
Remote: Time-stamped event sequence and captured waveforms ready for the protection engineer.
Record keeping
Manual: Paper registers and spreadsheets, transcribed and filed by hand.
Remote: Automatic historian with exportable reports, alarm acknowledgements and operator actions logged.

DEPLOYMENT

Deployed into the substation you already run

Existing yards and new-build substations follow the same sequence, planned around outage windows so the asset stays in service as far as possible.

Retrofit compatibility

Works with legacy and modern gear alike: potential-free contacts and analogue repeaters from older electromechanical equipment, Modbus TCP/RTU from meters and PLCs, and IEC 61850 (MMS / GOOSE) from the IEDs of modern digital substations — presented together on one dashboard.

Engineering software & firmware

Embedded firmware, data acquisition and the dashboard platform are engineered by the group’s technology company.

Meet the group companies
  1. STEP 01

    Site survey & signal list

    Walk-down of the yard and control room with your engineers; every point to be monitored is listed with its source, signal type and existing wiring.

    Output · Signal list · I/O schedule

  2. STEP 02

    Sensor & PLC installation

    Transmitters, probes and the yard PLC / marshalling kiosk are installed during a planned outage window agreed with the utility, without disturbing protection wiring.

    Output · Installed field I/O

  3. STEP 03

    Fibre laying & termination

    Optical fibre routed through existing cable trenches, spliced and terminated in patch panels, then loss-tested end to end.

    Output · Fibre test records

  4. STEP 04

    Gateway & dashboard commissioning

    Edge gateway, historian and SCADA / web dashboard brought online; every point is verified from field device to screen.

    Output · Point-to-point checks

  5. STEP 05

    Alarm set-point tuning

    Thresholds, trend alarms and escalation rosters set with the O&M team against each asset’s baseline and operating practice.

    Output · Alarm philosophy

  6. STEP 06

    Training & handover

    Operators and maintenance engineers trained on the console, alarms and reports; documentation and as-built drawings handed over.

    Output · As-builts · O&M manual

DEPLOYMENT PROPOSAL

Request a deployment proposal for your yard

Share the voltage class, bay count and the equipment you want supervised. Our engineers will come back with a signal list, architecture and installation plan around your outage windows.